Volatile Anesthetics

In this tutorial we review the modern volatile anesthetic agents used in everyday anesthesia practice: sevoflurane, desflurane and isoflurane. We begin by explaining the key pharmacological concepts that every anesthesia trainee should understand, including blood-gas partition coefficient, oil-gas partition coefficient, tissue-blood partition coefficient, potency, onset of action, emergence, and minimum alveolar concentration (MAC). We also show how MAC is applied in routine clinical practice to achieve and maintain an appropriate depth of anesthesia.

The tutorial then compares the three commonly used volatile agents, highlighting their individual advantages and limitations, including speed of induction and recovery, metabolism, pungency, suitability for inhalational induction, and low-flow anesthesia. Finally, we examine their physiological effects on the brain, spinal cord, respiratory system, cardiovascular system, and other organ systems, explaining why these effects matter during routine anesthesia.

Emergence From Anesthesia – Tissue Blood Partition Co-Efficient and Other Factors (2 tutorials)

Part 1 – Tissue Blood Partition Co-Efficients

This tutorial explains why emergence from volatile anesthesia depends on more than simply turning off the vaporizer. It reviews how blood gas partition coefficients influence onset, how oil gas partition coefficients relate to potency and MAC, and then focuses on tissue blood partition coefficients as a key determinant of recovery. The tutorial describes anesthetic uptake into blood, muscle, and fat during short, intermediate, and long cases, showing how tissue storage increases with time and with agent solubility. It also explains tissue back diffusion, where anesthetic stored in tissues continues to return to the blood and brain after the vaporizer is turned off, delaying wake-up. Finally, it compares volatile agents such as nitrous oxide, desflurane, sevoflurane, isoflurane, halothane, and methoxyflurane, emphasizing how lower tissue solubility produces faster, more predictable emergence.

Part 2 – Other Factors that Impact Emergence from Anesthesia

This tutorial examines the additional factors that determine how quickly a patient wakes after volatile anesthesia. It covers the concentration-flow ramp, fresh gas flow, alveolar ventilation, and cardiac output, explaining how these influence washout of anesthetic from the lungs and circulation. It discusses the effects of poor gas exchange, atelectasis, duration of surgery, higher inspired concentrations, and obesity on tissue loading and delayed emergence. The tutorial also reviews hysteresis and MAC awake, showing why patients can remain asleep at concentrations lower than those required for induction. Other important contributors such as hypothermia, opioids, benzodiazepines, propofol, dexmedetomidine, clonidine, ketamine, and nitrous oxide are included, along with a discussion of spontaneous ventilation versus intermittent positive pressure ventilation. The overall message is that emergence depends on both how efficiently the lungs clear anesthetic and how much anesthetic the body gives back